MEP projects · HVAC scope · Coordination
The HVAC Package for MEP Projects in Dubai
On most buildings the HVAC package is the largest and most space-hungry part of the MEP scope: big ducts, chilled-water or refrigerant pipework, plant on the roof and risers through every floor. It is also the package that clashes with everyone else. AGEC is an HVAC contractor. Our scope is air-conditioning, ventilation and air-filtration systems, installation and maintenance, and on an MEP project that is the package we take.
This page is deliberately specific. We deliver the HVAC package with our own teams and coordinate its interfaces with the electrical, plumbing, fire-protection and controls contractors, who are appointed separately. We do not offer those trades ourselves.
What we deliver: the HVAC package
The HVAC scope is where our engineers and installation teams work directly, from the first heat-load calculation to the commissioning report. It covers air-conditioning, ventilation and air-filtration systems, and that is the scope we take responsibility for.
- HVAC design: heat-load calculations, equipment selection, duct sizing and layout
- Supply and installation of VRF/VRV, DX, ducted split and chilled-water systems
- Ductwork fabrication and installation, insulation and air distribution
- Ventilation, fresh-air and exhaust systems
- Testing, adjusting, balancing and commissioning with documented results
- Maintenance after handover, including annual contracts
Other trades: coordinated, not delivered by us
A building also needs electrical, plumbing and drainage, fire fighting, fire alarm and controls. Those are carried out by their own specialist contractors, appointed by the client or the main contractor, and they are outside our scope. Our role is to make sure the HVAC design and installation fit with their work, and that the interfaces between them are settled before they reach site.
Interfaces that always need an owner are the power supply and isolators for HVAC equipment, condensate drainage routes, the points where our ductwork meets fire dampers and the fire alarm, and the link to the building controls. We supply and connect our own HVAC equipment only. For every other item, we agree in writing at the start of the project which contractor is responsible, so nothing is left without an owner.
Coordination: where MEP projects are won or lost
Most MEP problems are not equipment problems; they are space problems. Two services want the same ceiling void, a beam sits where a duct was drawn, or a drain has no fall. These are far cheaper to settle on a drawing than above a finished ceiling.
We coordinate the HVAC layout against the structure, ceilings and other services before fabrication, flag clashes in writing with a proposed resolution, and keep the coordinated drawings current as the design changes. Where a consultant or main contractor runs a BIM or coordination process we take part in it; where there is none we set up a simple clash-review routine for the HVAC interfaces.
- Clash review of ducts, pipework and equipment against structure and other services
- Ceiling-void and riser allocation agreed before fabrication
- Written interface list: power, drainage, controls and fire-alarm interfaces, with an owner for each
- Regular coordination with the consultant and main contractor
Shop drawings and submittals
Before anything is fabricated or ordered, the contractor submits shop drawings and equipment submittals for the consultant's approval. For HVAC this includes duct and pipework shop drawings, equipment data sheets and selection reports, sections at tight locations, builder's-work requirements and the testing and commissioning method statement.
Our team prepares HVAC shop drawings from the approved design and the coordinated layout, and issues them for approval with the supporting data. Work does not start on a package until its drawings are approved, which keeps changes on paper where they cost the least.
Authority approvals
Mechanical and ventilation works in Dubai involve authority requirements for the installation itself. Fire and life-safety systems, including smoke control and pressurisation, are designed and approved by the fire-protection designer and contractor, not by us. Where our HVAC system interfaces with them, for example a fire damper in our ductwork or shutdown of air handling units on alarm, we coordinate that interface and document our side of it.
We prepare the drawings and submit and follow up on approvals for you.
Testing, commissioning and handover
An HVAC package is not finished when the equipment is on the roof. Systems are tested, balanced and commissioned: airflows measured and adjusted, water or refrigerant circuits verified, controls tested against the sequence of operation, and results recorded. We work to the project specification first. Where it refers to them, we follow ASHRAE 111, SMACNA and CIBSE commissioning guidance and hand over the measured figures, not just a completion certificate.
After handover we keep the system running through annual maintenance contracts, so the people who built the system are the ones looking after it.
Who this suits
This suits projects where air-conditioning and ventilation are the dominant package: villas and villa communities, retail and F&B fit-outs, offices, gyms, clinics and data rooms. It also suits main contractors who want one accountable HVAC subcontractor with in-house design, installation and commissioning, rather than separate parties for each stage.
If you need one contractor for every trade on a building, we are not that contractor: we are the HVAC package within it, and we will work with the other trades your project appoints.
Common questions
Do you do the whole MEP package or only HVAC?
HVAC only. Our scope is air-conditioning, ventilation and air-filtration systems, installation and maintenance. Electrical, plumbing, fire fighting, fire alarm and controls are delivered by their own contractors, and we coordinate the HVAC interfaces with them.
Can you work under a main contractor or consultant?
Yes. We work to the consultant's approved drawings and specification, submit shop drawings and equipment submittals for approval before fabrication, and attend coordination meetings.
Who prepares the HVAC shop drawings?
Our team prepares them from the approved design and the coordinated layout, and we issue them for approval together with equipment data and the testing and commissioning method statement.
Do you handle authority approvals?
We prepare the drawings and submit and follow up on approvals for you.
Do you provide commissioning and handover documents?
Yes. HVAC systems are tested, balanced and commissioned, with measured airflows and settings recorded and handed over. We work to the project specification first. Where it refers to them, we follow ASHRAE 111, SMACNA and CIBSE guidance.
Do you maintain the systems after handover?
Yes, through annual maintenance contracts covering scheduled servicing and breakdown response.
Discuss the HVAC scope of your project
Send us the drawings or the scope. We reply on call and WhatsApp, 24/7.